Micro P.Hand.M.Vandc.Ando.R.P Analyzer

Supplied with Combination Glass pH Electrode (0-70ºC), Standard Buffer Tablets, Electrode Stand with Clamp, Dust Cover, Power Cord, Operational & Instruction Manual, Manufacturer Test Certificate & Warranty Card

Technical Specifications :

  • pH Range : 0-14 pH
  • Resolution : 0.01 pH
  • Temperature Range : 0.0 to 100ºC (Manual Compensation)
  • Display : 31/2 Digit LED Display
  • Power Supply : 230VAC ±10%, 50 Hz

 

Salient Features :

Calibration check facility & Calibration Error indication for 7.00 & 4.00 pH

 

 
> </div>
<div class=

Conductivity And T.D.S And Resistivity And c Analyzer

Supplied with Conductivity Cell K = 1.0, Temperature Probe, Electrode Stand with Clamp, Dust Cover, DC Adaptor, Operational & Instruction Manual, Manufacturer Test Certificate and Warranty Card.

Technical Specification :

Conductivity Range : 0 to 20.00, 200.0, 2000 µS/Cm; 2 to 20.00, 200.0 ms/cm
Conductivity Resolution : 0.001,0.01,0.1 µS/cm & 0.01, 0.001 mS/cm
TDS Range : 0 to 10.00, 100.0, 1000 ppm; 10.00, 100.0 ppt(1ppt=10,000ppm)
TDS Resolution : 0.001, 0.01, 0.1 ppm & 0.001, 0.01ppt
Range Selection : Auto / Manual Ranging

  • Temperature Range : 0 to 130.0ºC
  • Temperature Resolution : 0.1ºC
  • Temp. Compensation : Automatic & Manual
  • Temperature Coefficient : 0-10.000 % per ºC (Adjustable)
  • Suitable Cell Constant : 0.1, 0.5, 1.0 K
  • Adjustable Cell Constant : 0.09 to 1.1 K
  • Cond. to TDS Conv. Fac.: 0.40000 to 1.00000 (Adjustable)
  • Backlit LCD Display : 16 x 2 line Alphanumeric
  • Printer Capability : Yes - Parallel Port
  • Power Requirement : DC Adaptor
 
> </div>
<div class=

Karl Fischer Titrator

Supplied with 250ml Reaction Vessel, Auto Burette (25 x 0.1ml), 500ml Amber Color Reservoir, Dual Platinum Combined Electrode, Teflon Paddle, Teflon Assembly for holding, Electrode, Moisture Trap, Actuator Assembly, Operational & Instruction Manual and Manufacturer Test Certificate.

Optional :

  • Calibrated 25 ml Auto Burette having Min.Graduation of 0.1ml with Certificate
  • Auto Drain of Reaction Vesselm
 
> </div>
<div class=

Meltingandboiling Point Apparatus

Supplied with Melting Capillary one end sealed (Pack of 100 Nos) , Power Cord and Operational & Instruction Manual and Warranty Card.

Technical Specification :

Detection Principal : Automatic by photocell
Temperature Range : 5ºC Above Ambient to 400ºC
Heating before set point : Automatic Temperature Heating depending upon temp. diff.
Heating after Set point : Variable 0.5, 1.0 & 2.0 ºC - Selectable
Detection of Melting : a) Melting Point b) Melting Range
Oven Controller : Microcontroller Based

  • Temperature Resolution : 0.1ºC
  • Calibration : Multi Point Calibration Standard - as per Pharmacopia or Any users known standard.
  • Max. Heating Time : Less then 10 Minutes from 50ºC to 350ºC
  • Max. Cooling Time : Less then 10 Minutes from 350ºC to 50ºC
  • Melting Capillary : One Capillary (Single Channel)
  • Accuracy of Temp.:
  • Ambient +10ºC to 100ºC………… ± 0.2ºC.
  • 101ºC to 200ºC …………. ± 0.4ºC.
  • 200ºto 350ºC …………….. ± 0.5ºC.
 
> </div>
<div class=

Digital Flame Photometer Modelflamecal

Supplied with two filters (Na and K) , 2 1/2 Digit LED Display, Oil Free Air compressor, Air Filter with Pressure Regulator & Gauge, Atomizer Tube, Gas Lighter, Sample Beaker (05 Nos), LPG Tube, Air line PU Tube etc

Technical Specification :

Range : Na, K, & Li :1-100 ppm and Ca:15-100 ppm

  • Sensitivity : Na, K, & Li :0.5 ppm and Ca:15 ppm
  • Linearity : < 3%
  • Reproducibility : 2% CV for 20 samples
  • Detector : Photo Cell
  • Ignition System : Manual Ignition
  • Flame System : LPG & Dry Oil Free Air
  • Gas Control : Adjustable with Knob
  • Automiser : Axial Flow Type
  • Oil free Air Compressor : Supplied with Built-in Air Filter with Pressure Regulator & Gauge to deliver stable and moisture / oil free air supply.
  • Power Supply : 230 VAC ±10%, 50 Hz
 
> </div>
<div class=

Gas Handling And Purification System

Nitrogen Gas Line Consist of :

  • Moisture Filter consist of Molecular Sieve - 13X & Silica Gel, Length : 11"
  • Regenerable Type Indian Oxytrap
  • Inlet & Outlet Machine Sealed Type Stainless Steel Pressure Gauge
  • Brass Chrome Plated Pressure Regulator with SS Diaphragm
  • Brass Chrome Plated On/Off Valve
 
> </div>
<div class=

Laboratory Gas Generators

Tecnical Specifications :

  • Moisture Content < 2 ppm
  • Oxygen < 5 ppm
  • Total Hydro Carbon < 0.3 ppm
  • CO & CO2 < 2 ppm
  • Purity of Gas : UHP / GC Grade
  • Micron Particulates < 0.01 Micron
  • Capacity of Gas : 300 ml/Min at 6 kg/cm & 800 ml/Min at 6 kg/cm
  • Method of Purification : Pressure Swing Adsorption (PSA)
  • Room Temperature : 5 - 30ºC
  • Supply : 230VAC ± 10%,50Hz
 
> </div>
<div class=

Exhaust Flame Hood

Consist of :

  • SS 304 100 mm dia Pipe with Flange : 3 mtrs
  • SS 304 100 mm dia Bend with Flange : 01 Nos
  • Canopy with Adjustable CFM : 01 No having
  • Dampener : 01 No CFM can be controlled with help of dampner.
  • Blower with Motor : 01 Nos
 
> </div>
<div class=

Ultrasonic Bath (Sonicator)

 


   

  • Electric Supply : 170 – 245 VAC 50Hz Single Phase
  • Ultrasonic Power : As per Model watts average, 1000 Watts peak (with heater)
  • Ultrasonic Frequency : 33 +/- 3 KHz
  • Ultrasonic Generator : Micro Controller base Digital Timer.
  • With latest MOSFET base technology.
  • With Auto Degassing facility.
  • Automatic frequency tuning for maximum output
  • Modular generator for easier modification/servicing.
 
Automatic Melting Apparatus * Boiling Point Apparatus * Conductivity And T. D. S And Resistivity And C Analyzer * Digital Flame Photometer Modelflamecal * Exhaust Flame Hood * Flow Diagram For Gas Handling * Gas Control Module * Gas Handling And Purification System * Karl Fischer Titrator * Laboratory Gas Generators * Low Pressure Gas Changeover Module * Meltingandboiling Point Apparatus * Micro P. Hand. M. Vandc. Ando. R. P Analyzer * Ministation * Photo Meters * Purification System With Accessories * Ultrasonic Bath (Sonicator)